Your shopping cart is empty.
Regional Anesthesia and Ultrasound Central Line Training Model
Our realism makes your training better.
Better training at a lower cost.
"Ultrasound Andy" in recognition of Dr. Andy Rosenberg's Vision and Inspiration
Download:
Also Available:
Replacement Part:
GTSimulators by Global Technologies
CAE Healthcare Authorized Distributor.
SpecificationsNext generation upper torso ultrasound central line and regional anesthesia mannequin
Extremely realistic external and internal anatomy for ultrasound guided or blind insertion training
The most realistic and durable central venous catheter and nerve block ultrasound training model available anywhere
Excellent for training clinicians in the psychomotor skills associated with ultrasound guided central line placement
training
Superb imaging characteristics optimize your training; simulated tissue matches the acoustic properties of real
human tissue
For use with any ultrasound system, no computer simulation or software necessary
Self-healing tissue offers users tremendous durability – minimizing the need for replacement parts and providing a
low cost of ownership
Teach, learn and practice on an extremely realistic model rather than a live patient, reducing overall risk
Anatomically correct; casted from a live patient and constructed from a digital human file
Regional anesthesia anatomy includes: supraclavicular nerves, interscalene nerves, infraclavicular nerves and
enhanced access of the posterior interscalene nerve block approach The brachial plexus can be injected with
simulated anesthetics to verify needle tip location and to practice the entire anesthesia procedure
Injected simulated anesthetics are expelled allowing for repeated use
Venous anatomy includes: internal jugular vein (IJ), brachiocephalic vein, subclavian vein and axillary vein
Arterial anatomy includes: carotid artery, subclavian artery and axillary artery
Simulated superior vena cava, right atrium and right ventricle allows clinicians to fully thread guidewires and
catheters without resistance
Internal landmarks for superior realism include the trachea, manubrium and clavicle
Veins are compressible using mild pressure while the arteries remain uncompressed
Arterial pulsations simulated using provided hand bulb or optional integrated automated pumping system
Positive fluid flow in the vessels; model is prefilled with red fluid in the arteries and blue fluid in the veins
Easy to refill vessels with ultrasound refill solution using QuickFill™ ports
Excellent imaging quality using any ultrasound system
Practice using ultrasound system controls
No special storage needs
Patented technology
Purchase includes 2 bottles of simulated blood refill solution; one red (arterial), one blue (venous). 235mls each
bottle
Soft storage case available for purchase (BPH662-A)
ANATOMY:Internal jugular (IJ)
Subclavian vein
Infraclavicular vein
Supraclavicular vein
Axillary vein
Superior vena cava (SVC)
Right atrium
Right ventricle
Supraclavicular nerves
Interscalene nerves
Infraclavicular nerves
Enhanced access of the posterior interscalene nerve block
DIMENSIONS:Size: 21.5" wide x 22.5" high x 9" deep (55 cm x 57 cm x 23 cm)
Weight: 28 lbs. (hand pump) (12.7 kg), 32 lbs. (auto pump) (14.5 kg)
WARRANTY:1 Yr Manufacturer's Warranty
Only use with CAE Blue Phantom Ultrasound Refill Fluid
Only use with 18-21 gauge, sharp, unbent needles
0.0 lb
🎄 HOLIDAY SAVINGS - Ends Dec 31 🎄
Discount is automatically applied at checkout.
Regional Anesthesia and Ultrasound Central Line Training Model
Item # BPHNB670-HP
$8,088.30
Need an estimate?
Click Add To Quote
Features & Specifications
-
by
A trusted GT partner -
FREE Shipping
U.S. Contiguous States Only -
Gov't pricing
Available upon request
Frequently Bought Together
Regional Anesthesia and Ultrasound Central Line Training Model
Blue Phantom’s new Ultrasound Central Line and Regional Anesthesia Training Model is
the most realistic central line and nerve block simulator available anywhere. Cast from a live human, our innovative
LifeCast™ modeling approach provides the most realistic external landmarks while the internal anatomy is based on
digital human files. This ultra-durable mannequin incorporates all of the anatomy required to gain proficiency in
using ultrasound for central line placement and peripheral nerve blocks. This model is excellent for both ultrasound
guided and blind insertion central line procedural training. Our ultra-durable self-healing tissue withstands
tremendous use, minimizing the need for replacement parts. Blue Phantom allows clinicians to teach, practice and
learn central line and regional anesthesia procedures repeatedly without the need to worry about cost per use.
Perform complete central line placements of the internal jugular and subclavian vein - including needles,
guidewires, dilation, and threading of catheters.
Our realism makes your training better.
Blue Phantom’s simulated tissue, SimulexUS™, matches the acoustic properties of human
tissue, providing clinicians with an extremely realistic training scenario. Use your ultrasound system without
having to adjust the ultrasound system controls unrealistically. No computer simulation or software necessary. Each
of our training models is designed to offer users of all levels superior realism, reliability and durability.
Better training at a lower cost.
Each model offers anatomically correct brachial plexus and vascular access anatomy of
the upper thorax and neck. This next generation ultrasound mannequin contains improved anatomy for nerve blocks
including the supraclavicular nerves, interscalene nerves, infraclavicular nerves and enhanced access of the
posterior interscalene nerve block approach. Vascular access anatomy includes the internal jugular vein (IJ),
brachiocephalic vein, subclavian vein, axillary vein, carotid artery, subclavian artery and axillary artery. The
model can be accessed via the internal jugular (IJ), subclavian, infraclavicular and supraclavicular approach as
well as the axillary vein. The simulated superior vena cava, right atrium and right ventricle offer users the
ability to fully thread guidewires, dilators and catheters without resistance just as you would expect with a live
patient. This central line simulator with regional anesthesia option also includes internal landmarks such as the
trachea, suprasternal notch, manubrium and clavicle. This model is excellent utilizing traditional external
landmarks for blind insertion central line placement or use ultrasound to guide the central venous access procedure.
The brachial plexus can be injected with simulated anesthetics to verify needle tip location and to practice the
entire anesthesia procedure. Injected simulated anesthetics are expelled allowing for repeated use.
"Ultrasound Andy" in recognition of Dr. Andy Rosenberg's Vision and Inspiration
Designed to the rigorous standards of Dr. Andy Rosenberg, the Chair of Anesthesiology
at NYU’s Hospital of Joint Diseases, the product bears his name in recognition of his collaboration in the model’s
design. Dr. Rosenberg is a pioneer in the field of regional anesthesia simulation and received no compensation for
his input but rather preferred to see his vision come to life so that clinicians could better care for patients in
their communities. A vision that everyone here at Blue Phantom shares.
Arterial pulsation can be simulated via the manual hand bulb to differentiate between arteries and veins via ultrasound. Users can also add the optional fully integrated automated pump system for additional ease. The veins in our central line mannequin are also compressible using mild pressure while the arteries remain uncompressed. Vessel identification is made easy immediate positive fluid flow of the vein versus artery. The venous system is prefilled with blue fluid and the arterial system is prefilled with red fluid. Users can positively identify the targeted vessels and receive immediate feedback as to successful or unsuccessful vascular access. Re-filling venous and arterial fluid removed during central venous catheter procedures by using the provided QuickFill™ ports or and I.V. bag to continually refill the vessels during training.
Arterial pulsation can be simulated via the manual hand bulb to differentiate between arteries and veins via ultrasound. Users can also add the optional fully integrated automated pump system for additional ease. The veins in our central line mannequin are also compressible using mild pressure while the arteries remain uncompressed. Vessel identification is made easy immediate positive fluid flow of the vein versus artery. The venous system is prefilled with blue fluid and the arterial system is prefilled with red fluid. Users can positively identify the targeted vessels and receive immediate feedback as to successful or unsuccessful vascular access. Re-filling venous and arterial fluid removed during central venous catheter procedures by using the provided QuickFill™ ports or and I.V. bag to continually refill the vessels during training.
Download:
Also Available:
Replacement Part:
GTSimulators by Global Technologies
CAE Healthcare Authorized Distributor.
Shipping Dimensions and Weight:
- Size: 26 x 23 x 13 in
- Weight: 26 lb.
Specifications
ANATOMY:
DIMENSIONS:
WARRANTY:
Made in the USA
GTSimulators by Global Technologies
CAE Healthcare Authorized Distributor.
by Item # BPHNB670-HP
— Regional Anesthesia and Ultrasound Central Line Training Model
$8,088.30
Add to Cart
Add to Quote