Your shopping cart is empty.
Arthur | MedVision Pediatric Patient Simulator, Dark Skin
Item # ART-JUNIORKIT-001DRequest a quote for pricing
Need an estimate?
Click Add To Quote
Arthur represents a 5-8 year old boy that simulates a wide range of conditions.
From a healthy talking child to being unresponsive with no vital signs, Arthur provides meaningful learning experiences through his extensive range of features.
When caring for a young child, communication skills are as critical as the technical skills required to manage pediatric emergencies.
Arthur has been designed to support those working in child health to effectively communicate, assess, diagnose and treat young patients in a diverse range of critical scenarios and in a variety of clinical settings.
- Realistic airway
- Real mechanical ventilator compatibility
- Real devices can be used for ECG, pulse monitoring, defibrillation
- and BP monitoring
- Cricothyrotomy, needle decompression of tension pneumothorax
- CPR with comprehensive performance assessment
- On-site installation and training included
-
by
A trusted GT partner -
1-Year Warranty
Provided by manufacturer -
Gov't pricing
Available upon request
Essential is a 5-8 year old pediatric patient simulator developed and produced by Medvision, created, to bring pediatric patient care to a whole new level. We took the best from our LEONARDO simulator and carefully carried it to Arthur, resulting in Arthur’s conformity to all pediatric care requirements and standards.
ARTHUR
Bringing pediatric patient care to a whole new level
Innovations for life
Essential is a 5-8 year old pediatric patient simulator developed and produced by Medvision, created, to bring pediatric patient care to a whole new level. We took the best from our LEONARDO simulator and carefully carried it to Arthur, resulting in Arthur’s conformity to all pediatric care requirements and standards.
- Programmable blinking rate, pupil size, pupillary light reflex
- Anatomically accurate upper airway supporting intubation
- Mechanical ventilation using a real medical ventilator
- Compatibility with a real defibrillator
- Cricothyrotomy and needle decompression of a tension pneumothorax
- CPR with performance assessment, i.e. hands placement, rate, depth
- Realistic skin, height and weight, i.e. 122 cm and 20.5 kg.
Basic physical examination
Arthur will assess all of your actions during resuscitation and then provide detailed feedback.
Powerful and intuitive, a perfect symbiosis of hardware and software: access our ever-expanding
library of clinical cases or create your own.
Automatic drug, injected volume and speed recognition
Orotracheal intubation
- Spontaneous breathing
- Programmable chest rise and fall
- Programmable respiratory rate
- Anatomically accurate upper airway
- Mechanical ventilation using a real medical ventilator
- Normal and abnormal breath sounds
- Pulse oximetry and plethysmography
- Programmable respiratory complications
- Programmable bilateral lung volume during mechanical ventilation
Blinking and pupillary light reflex
Pupillary light reflex, programmable bilateral blinking rate and pupil size for any of your simulation scenarios
FEATURES
- Anatomically accurate upper airway
- Orotracheal and nasotracheal intubation
- Head tilt, chin lift, jaw thrust
- Laryngeal mask airway insertion
- Pneumothorax
- Sellick manoeuvre
- Positive pressure ventilation
- Programmable airway resistance
- Pharyngeal airflow obstruction
- Esophageal intubation
- BVM ventilation
- Cyanosis and acrocyanosis
- Bilateral chest rise and fall
- Programmable bilateral bronchi resistance
- Intubation depth detection and logging
- Tongue edema
- Laryngospasm
- Spontaneous breathing
- Programmable respiratory complications
- Programmable respiratory rate
- Respiratory rate synced to patient monitor vital signs
- Programmable chest rise and fall
- Mechanical ventilation (PCV and VCV) PEEP (up to 40 cm H2O)
- Variable bronchi resistance
- Audible needle decompression with realistic feedback
- Auscultation of heart sounds (5 points), lung anterior sounds (5 points), lung posterior sounds (4 points), bowel sounds (4 points)
- Independent normal/abnormal heart sounds
- Independent normal/abnormal lung sounds
- Normal/abnormal bowel sounds
- Auscultation of Korotkoff sounds
- Programmable bilateral chest rise and fall, synced with breathing
- Rich library of ECG rhythms
- ECG heart rate of 20 to 200 bpm
- Real ECG electrodes
- Anatomically accurate landmarks to position your hands for chest compressions
- Chest compressions
- Defibrillation, cardioversion and cardiac pacing using real devices
- Defibrillator pads correct placement and logging
- Defibrillation in manual and automatic modes
- Successful compressions with their logging and effect on HR and ECG
- Cyanosis
- Programmable pulse strength
- Tonic and clonic seizures
- Programmable blinking rate
- Programmable unequal pupil sizes (anisocoria)
- Realistic chest compressions
- Automatic activity log, displaying all user actions
- Depth, frequency, hands placement assessment and log
- Ventilation volume
- Manual configuration of CPR protocols
- Printable detailed CPR assessment
- Intravenous injections with automatic drugs recognition (preinstalled catheter)
- Intraosseous access (tibia, bilateral)
- Rich library of vocal sounds (moaning, coughing, pre-recorded words and phrases)
- Use of a microphone to transmit information through the simulator
- Realistic teeth, soft cheeks and gums
- Pre-installed themes, scenarios, programs and the Scenario Constructor software to design your own scenario
- Realistic bone structure, palpable ribs, kneecaps and many more