The AirSim® Pierre Robin, based on a 0-6 month old, was developed in collaboration with clinicians from Children’s
Hospital Los Angeles. This realistic training manikin highlights difficult airway management techniques for infants
with Pierre Robin Sequence/Syndrome (PRS). AirSim® X airway with 5-year warranty certified for over 20,000
intubation
cycles.
Pediatric Difficult Airway Trainer
As a result of their unique anatomy, infants with Pierre Robin Syndrome are more likely to present difficulties in
airway management. Airway management in patients with uncorrected PRS should be anticipated as potentially very
difficult1 and requires advanced training in difficult pediatric airway management.
Pierre Robin Syndrome airway management
The AirSim Pierre Robin X allows training in the full range of supraglottic devices.
The AirSim® Pierre Robin X anatomically correct airway has been constructed based on real CT data of a
six-month-old infant and exhibits various congenital defects of an infant with PRS including: Significant mandibular
hypoplasia, Micrognathia, Glossoptosis, Cleft palate, Bifid uvula.
Difficult Pediatric Airway Management Trainer
In addition to the factors specific to Pierre Robin sequence, difficult airways in infants can be caused by the same
factors complicating airway management in adults, including limited head extension, reduced mandibular space and
increased tongue thickness.2
Airway management skills are fundamental to anaesthesiology. The AirSim Pierre Robin X manikin provides an advanced
medical training experience to improve patient safety and outcomes.
Our infant difficult airway trainer provides realistic feedback during and facilitates training in several airway
management procedures including: Bag-Valve-Mask Ventilation, Supraglottic device insertion, Naso and orotracheal
intubation, Direct And Video Fiberoptic Laryngoscopy.
Pediatric Airway Obstruction Management
The ‘real feel’ skin covering and accurate anatomy create a more realistic training experience.
Upper airway obstruction is frequently the cause of respiratory distress and failure in pediatric patients 3 with
the most common causes being infection, airway swelling and foreign body airway obstruction.
The congenital defects associated with PRS can also affect upper airway patency, as can enlarged tonsils or
adenoids.
Techniques and tools for pediatric airway obstruction management include: Properly performed bag-valve-mask
ventilation, Use of oral or nasopharyngeal airways during ventilation, Supraglottic devices including LMA, Direct
laryngoscopy, Fiberoptic bronchoscope and supraglottic airway used to advance an airway exchange catheter as a
conduit for
intubation.
The AirSim Pierre Robin X trainer allows anesthesiologists and other medical professionals to practice
tracheal intubation, mask ventilation and other techniques to overcome the unique challenges presented by
this syndrome.
Product Features
Accurate representation of a pediatric patient with Pierre Robin Sequence
Anatomically correct details for true to life medical procedure training
Ideal for practicing airway obstruction management techniques
Provides realistic feedback during airway management & laryngoscopy practice
‘Real feel’ skin covering for added realism
Anatomically correct AirSim® X airway with 5-year warranty certified for over 20,000 intubation
cycles
Medical Procedure Training
Double nasotracheal intubation
Endotracheal tube insertion
Bag-valve-mask (BVM) ventilation techniques
Full range of supraglottic devices
Direct and video laryngoscopy
The Pierre Robin X airway manikin is compatible with a full range of supraglottic devices. We recommend
the following equipment sizes for optimal performance:
3.5-4.0 mm ID for oral intubation
Size 1 for supraglottic devices
Size 1 for video-laryngoscopy
AirSim Pierre Robin X weight: Approx. 4.41 lbs
Package Contents
1 Carrier Case
1 Bottle of TruCorp® Lubrication (100ml)
3 Baby Lung Bags replicating 2 lungs & stomach
2 sets of adhesive pads (attachable to suction cups for increased stability if required)
Download:
GTSimulators by Global Technologies TruCorp Authorized Dealer
The AirSim X airway has been designed using CT DICOM data from real patients, to
provide trainees with a lifelike intubation training solution. The internal airway is
anatomically
accurate and will guarantee 20,000+ intubation cycles when used correctly. TruCorp is proud to
offer
a 5-year warranty on the AirSim X airway.
This manikin was developed in collaboration with clinicians from Children’s
Hospital Los Angeles to highlight difficult airway management techniques on infants with Pierre
Robin Syndrome.
The internal anatomy features various congenital defects of an infant with PRS including:
Lubrication is the only consumable required for ongoing training using the AirSim
Pierre Robin X. TruCorp’s lubrication is a cost-efficient, water-soluble solution and is supplied in
a 100ml bottle. Please contact our sales team to purchase.
We recommend TruCorp’s lubrication for best practice, but alternatives can be
used provided they are water-soluble lubricants. Please do not use silicone-based products as
they
will degrade the materials.
>
No, this training manikin is delivered ready to use so you can begin training
straight away! Generously spray the oral/nasal passages and equipment with the lubrication
provided.
Yes, if successfully intubated the two lung bags will inflate. If the airway
device is incorrectly placed in the esophagus, the stomach bag will inflate.
The AirSim Pierre Robin X manikin comes with a 5-year warranty on the AirSim X
airway and a 1-year warranty on all other parts. Warranty begins from the date of delivery.
Another great benefit of this product is its modular design. This means spare
parts can be ordered and interchanged at your location by your team. Please contact us and
provide
the serial number (found under the manikin base) and an image/video of the issue. If it meets
the
warranty conditions TruCorp will provide the required parts free of charge. If the warranty has
expired, our sales team will provide a quote.
Please store the manikin in clean, dry conditions away from heat and direct
sunlight. Avoid contact with metals, solvents, oils or greases and strong detergents. When the
product is not in use please store in the black carrier case provided.
Thoroughly wash the AirSim X airway in warm water. Please use warm soapy water or similar
until
all visible foreign matter and residue are removed.
Mild detergents or enzymatic cleaning agents may be used on the airway at the proper
dilution.
The detergent must not contain skin or mucous membrane irritants.
Please do not use any of the following when cleaning the AirSim product range:
• Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g.
Cidex®)
• Ethylene oxide, phenol-based cleaners, or iodine-containing cleaners
In response to the recent COVID-19 pandemic, we recommend this additional step to ensure the
product is fully sanitized:
Generously spray alcohol spray or gel (minimum 75% alcohol) and wipe off. Repeat 3-4 times
to
fully disinfect the product. This can be done on the silicone skin and the latex airway.
• Item # PR10000X
• By TruCorp Ltd — A trusted GT Partner.
• 5-Year Warranty provided by the manufacturer.
Description:
AirSim Pierre Robin X Model
The AirSim® Pierre Robin, based on a 0-6 month old, was developed in collaboration with clinicians from Children’s
Hospital Los Angeles. This realistic training manikin highlights difficult airway management techniques for infants
with Pierre Robin Sequence/Syndrome (PRS). AirSim® X airway with 5-year warranty certified for over 20,000
intubation
cycles.
Pediatric Difficult Airway Trainer
As a result of their unique anatomy, infants with Pierre Robin Syndrome are more likely to present difficulties in
airway management. Airway management in patients with uncorrected PRS should be anticipated as potentially very
difficult1 and requires advanced training in difficult pediatric airway management.
Pierre Robin Syndrome airway management
The AirSim Pierre Robin X allows training in the full range of supraglottic devices.
The AirSim® Pierre Robin X anatomically correct airway has been constructed based on real CT data of a
six-month-old infant and exhibits various congenital defects of an infant with PRS including: Significant mandibular
hypoplasia, Micrognathia, Glossoptosis, Cleft palate, Bifid uvula.
Difficult Pediatric Airway Management Trainer
In addition to the factors specific to Pierre Robin sequence, difficult airways in infants can be caused by the same
factors complicating airway management in adults, including limited head extension, reduced mandibular space and
increased tongue thickness.2
Airway management skills are fundamental to anaesthesiology. The AirSim Pierre Robin X manikin provides an advanced
medical training experience to improve patient safety and outcomes.
Our infant difficult airway trainer provides realistic feedback during and facilitates training in several airway
management procedures including: Bag-Valve-Mask Ventilation, Supraglottic device insertion, Naso and orotracheal
intubation, Direct And Video Fiberoptic Laryngoscopy.
Pediatric Airway Obstruction Management
The ‘real feel’ skin covering and accurate anatomy create a more realistic training experience.
Upper airway obstruction is frequently the cause of respiratory distress and failure in pediatric patients 3 with
the most common causes being infection, airway swelling and foreign body airway obstruction.
The congenital defects associated with PRS can also affect upper airway patency, as can enlarged tonsils or
adenoids.
Techniques and tools for pediatric airway obstruction management include: Properly performed bag-valve-mask
ventilation, Use of oral or nasopharyngeal airways during ventilation, Supraglottic devices including LMA, Direct
laryngoscopy, Fiberoptic bronchoscope and supraglottic airway used to advance an airway exchange catheter as a
conduit for
intubation.
The AirSim Pierre Robin X trainer allows anesthesiologists and other medical professionals to practice
tracheal intubation, mask ventilation and other techniques to overcome the unique challenges presented by
this syndrome.
Product Features
Accurate representation of a pediatric patient with Pierre Robin Sequence
Anatomically correct details for true to life medical procedure training
Ideal for practicing airway obstruction management techniques
Provides realistic feedback during airway management & laryngoscopy practice
‘Real feel’ skin covering for added realism
Anatomically correct AirSim® X airway with 5-year warranty certified for over 20,000 intubation
cycles
Medical Procedure Training
Double nasotracheal intubation
Endotracheal tube insertion
Bag-valve-mask (BVM) ventilation techniques
Full range of supraglottic devices
Direct and video laryngoscopy
The Pierre Robin X airway manikin is compatible with a full range of supraglottic devices. We recommend
the following equipment sizes for optimal performance:
3.5-4.0 mm ID for oral intubation
Size 1 for supraglottic devices
Size 1 for video-laryngoscopy
AirSim Pierre Robin X weight: Approx. 4.41 lbs
Package Contents
1 Carrier Case
1 Bottle of TruCorp® Lubrication (100ml)
3 Baby Lung Bags replicating 2 lungs & stomach
2 sets of adhesive pads (attachable to suction cups for increased stability if required)
Download:
GTSimulators by Global Technologies TruCorp Authorized Dealer
The AirSim X airway has been designed using CT DICOM data from real patients, to
provide trainees with a lifelike intubation training solution. The internal airway is
anatomically
accurate and will guarantee 20,000+ intubation cycles when used correctly. TruCorp is proud to
offer
a 5-year warranty on the AirSim X airway.
This manikin was developed in collaboration with clinicians from Children’s
Hospital Los Angeles to highlight difficult airway management techniques on infants with Pierre
Robin Syndrome.
The internal anatomy features various congenital defects of an infant with PRS including:
Lubrication is the only consumable required for ongoing training using the AirSim
Pierre Robin X. TruCorp’s lubrication is a cost-efficient, water-soluble solution and is supplied in
a 100ml bottle. Please contact our sales team to purchase.
We recommend TruCorp’s lubrication for best practice, but alternatives can be
used provided they are water-soluble lubricants. Please do not use silicone-based products as
they
will degrade the materials.
>
No, this training manikin is delivered ready to use so you can begin training
straight away! Generously spray the oral/nasal passages and equipment with the lubrication
provided.
Yes, if successfully intubated the two lung bags will inflate. If the airway
device is incorrectly placed in the esophagus, the stomach bag will inflate.
The AirSim Pierre Robin X manikin comes with a 5-year warranty on the AirSim X
airway and a 1-year warranty on all other parts. Warranty begins from the date of delivery.
Another great benefit of this product is its modular design. This means spare
parts can be ordered and interchanged at your location by your team. Please contact us and
provide
the serial number (found under the manikin base) and an image/video of the issue. If it meets
the
warranty conditions TruCorp will provide the required parts free of charge. If the warranty has
expired, our sales team will provide a quote.
Please store the manikin in clean, dry conditions away from heat and direct
sunlight. Avoid contact with metals, solvents, oils or greases and strong detergents. When the
product is not in use please store in the black carrier case provided.
Thoroughly wash the AirSim X airway in warm water. Please use warm soapy water or similar
until
all visible foreign matter and residue are removed.
Mild detergents or enzymatic cleaning agents may be used on the airway at the proper
dilution.
The detergent must not contain skin or mucous membrane irritants.
Please do not use any of the following when cleaning the AirSim product range:
• Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g.
Cidex®)
• Ethylene oxide, phenol-based cleaners, or iodine-containing cleaners
In response to the recent COVID-19 pandemic, we recommend this additional step to ensure the
product is fully sanitized:
Generously spray alcohol spray or gel (minimum 75% alcohol) and wipe off. Repeat 3-4 times
to
fully disinfect the product. This can be done on the silicone skin and the latex airway.