Our AirSim® model is ideal for training in airway management and awake fiberoptic intubation. It features the
uniquely constructed AirSim® airway for realistic feedback during airway management procedures. Visually and
anatomically correct, the nasal cavity and airway include important internal landmarks for training in nasotracheal
intubation and nasally directed fiber optic examination.
Airway Management Trainer Head for Intubation & Examination Practice
The AirSim® nasal passage was developed to provide an anatomically correct nasal cavity including important
landmarks such as the turbinates for a realistic training experience in nasal intubation procedures. True to life
neck tilt, jaw thrust and chin facilitate practice in bag-valve-mask ventilation techniques.
Endotracheal, Orotracheal & Nasotracheal Intubation Training
The TruCorp AirSim intubation head is ideal for practicing Combi tube insertion, nasogastric tube insertion and the
full range of supraglottic device insertion including nasopharyngeal and oropharyngeal airways.
Product Features
Innovative AirSim® airway and nasal cavity created from CT DICOM data
Anatomically correct internal features and visually accurate landmarks in airway & nasal passage
Inflatable tongue with lifelike texture can simulate edema
Replaceable lung bags inflate with successful ventilation
Esophagus and replaceable bag representing stomach
Medical Procedure Training
Single nasotracheal intubation
Full range of supraglottic device insertion
Direct laryngoscopy
Fibre optic intubation & examination
Endotracheal tube insertion
Combi tube insertion
Nasogastric (NG) tube insertion techniques
Single lung isolation techniques
Durable Airway Trainer For Teaching
This model withstands continuous and repeated use in medical procedure training, making it ideal for a
classroom setting, and as an airway demonstration model for device manufacturers and educators.
The AirSim airway trainer is compatible with a full range of supraglottic devices. We recommend the
following equipment sizes for optimal performance:
7.0-7.5 mm ID for nasal intubation
8.0-9.0 mm ID for oral intubation
Size 3-5 for LMA laryngeal masks
Similar respective sizes for other supraglottic devices
AirSim Multi Model weight: Approx. 7.27 lbs
Package Contents
1 Carrier Case
1 Bottle of TruCorp Lubrication
3 Adult Lung Bags replicating 2 lungs & stomach
2 sets of adhesive pads (attachable to suction cups for increased stability if required)
Download:
GTSimulators by Global Technologies TruCorp Authorized Dealer
The AirSim airway has been designed using CT DICOM data from real patients, to provide trainees
with a lifelike intubation training solution. The internal airway is anatomically accurate and
will guarantee 20,000+ intubation cycles when used correctly. This manikin also features bronchi
to the 4th generation.
Lubrication is the only consumable required for ongoing training using the AirSim. TruCorp’s
lubrication is a cost-efficient, water-soluble solution and is supplied in a 100ml bottle.
Please
contact our sales team to purchase.
We recommend TruCorp’s lubrication for best practice, but alternatives can be used provided they
are water-soluble lubricants. Please do not use silicone-based products as they will degrade the
materials.
No, this training manikin is delivered ready to use so you can begin training straight away!
Simply ensure the head is in the correct position (sniffing or neutral) and generously spray the
oral/nasal passages and equipment with the lubrication provided.
Yes, if successfully intubated the two lung bags will inflate. If the airway device is
incorrectly placed in the esophagus, the stomach bag will inflate.
The tongue can be inflated to simulate tongue edema. Attach an empty syringe to the red connector
located near the chin and insert approx. 20ml of air.
Please contact us and provide the serial number (found under the manikin base) and an
image/video of the issue. If it meets the warranty conditions TruCorp will repair free of
charge. If warranty has expired, our sales team will provide a quote for repair.
Please store the manikin in clean, dry conditions away from heat and direct sunlight. Avoid
contact with metals, solvents, oils or greases and strong detergents. When the product is not in
use please store in the black carrier case provided.
Thoroughly wash the AirSim X airway in warm water. Please use warm soapy water or similar
until
all visible foreign matter and residue are removed.
Mild detergents or enzymatic cleaning agents may be used on the airway at the proper
dilution.
The detergent must not contain skin or mucous membrane irritants.
Please do not use any of the following when cleaning the AirSim product range:
• Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g.
Cidex®)
• Ethylene oxide, phenol-based cleaners, or iodine-containing cleaners
In response to the recent COVID-19 pandemic, we recommend this additional step to ensure the
product is fully sanitized:
Generously spray alcohol spray or gel (minimum 75% alcohol) and wipe off. Repeat 3-4 times
to
fully disinfect the product. This can be done on the silicone skin and the latex airway.
• Item # AA11100
• By TruCorp Ltd — A trusted GT Partner.
• 1-Year Warranty provided by the manufacturer.
Description:
AirSim Multi Model with Nasal Passage
Our AirSim® model is ideal for training in airway management and awake fiberoptic intubation. It features the
uniquely constructed AirSim® airway for realistic feedback during airway management procedures. Visually and
anatomically correct, the nasal cavity and airway include important internal landmarks for training in nasotracheal
intubation and nasally directed fiber optic examination.
Airway Management Trainer Head for Intubation & Examination Practice
The AirSim® nasal passage was developed to provide an anatomically correct nasal cavity including important
landmarks such as the turbinates for a realistic training experience in nasal intubation procedures. True to life
neck tilt, jaw thrust and chin facilitate practice in bag-valve-mask ventilation techniques.
Endotracheal, Orotracheal & Nasotracheal Intubation Training
The TruCorp AirSim intubation head is ideal for practicing Combi tube insertion, nasogastric tube insertion and the
full range of supraglottic device insertion including nasopharyngeal and oropharyngeal airways.
Product Features
Innovative AirSim® airway and nasal cavity created from CT DICOM data
Anatomically correct internal features and visually accurate landmarks in airway & nasal passage
Inflatable tongue with lifelike texture can simulate edema
Replaceable lung bags inflate with successful ventilation
Esophagus and replaceable bag representing stomach
Medical Procedure Training
Single nasotracheal intubation
Full range of supraglottic device insertion
Direct laryngoscopy
Fibre optic intubation & examination
Endotracheal tube insertion
Combi tube insertion
Nasogastric (NG) tube insertion techniques
Single lung isolation techniques
Durable Airway Trainer For Teaching
This model withstands continuous and repeated use in medical procedure training, making it ideal for a
classroom setting, and as an airway demonstration model for device manufacturers and educators.
The AirSim airway trainer is compatible with a full range of supraglottic devices. We recommend the
following equipment sizes for optimal performance:
7.0-7.5 mm ID for nasal intubation
8.0-9.0 mm ID for oral intubation
Size 3-5 for LMA laryngeal masks
Similar respective sizes for other supraglottic devices
AirSim Multi Model weight: Approx. 7.27 lbs
Package Contents
1 Carrier Case
1 Bottle of TruCorp Lubrication
3 Adult Lung Bags replicating 2 lungs & stomach
2 sets of adhesive pads (attachable to suction cups for increased stability if required)
Download:
GTSimulators by Global Technologies TruCorp Authorized Dealer
The AirSim airway has been designed using CT DICOM data from real patients, to provide trainees
with a lifelike intubation training solution. The internal airway is anatomically accurate and
will guarantee 20,000+ intubation cycles when used correctly. This manikin also features bronchi
to the 4th generation.
Lubrication is the only consumable required for ongoing training using the AirSim. TruCorp’s
lubrication is a cost-efficient, water-soluble solution and is supplied in a 100ml bottle.
Please
contact our sales team to purchase.
We recommend TruCorp’s lubrication for best practice, but alternatives can be used provided they
are water-soluble lubricants. Please do not use silicone-based products as they will degrade the
materials.
No, this training manikin is delivered ready to use so you can begin training straight away!
Simply ensure the head is in the correct position (sniffing or neutral) and generously spray the
oral/nasal passages and equipment with the lubrication provided.
Yes, if successfully intubated the two lung bags will inflate. If the airway device is
incorrectly placed in the esophagus, the stomach bag will inflate.
The tongue can be inflated to simulate tongue edema. Attach an empty syringe to the red connector
located near the chin and insert approx. 20ml of air.
Please contact us and provide the serial number (found under the manikin base) and an
image/video of the issue. If it meets the warranty conditions TruCorp will repair free of
charge. If warranty has expired, our sales team will provide a quote for repair.
Please store the manikin in clean, dry conditions away from heat and direct sunlight. Avoid
contact with metals, solvents, oils or greases and strong detergents. When the product is not in
use please store in the black carrier case provided.
Thoroughly wash the AirSim X airway in warm water. Please use warm soapy water or similar
until
all visible foreign matter and residue are removed.
Mild detergents or enzymatic cleaning agents may be used on the airway at the proper
dilution.
The detergent must not contain skin or mucous membrane irritants.
Please do not use any of the following when cleaning the AirSim product range:
• Germicides, disinfectants, or chemical agents such as glutaraldehyde (e.g.
Cidex®)
• Ethylene oxide, phenol-based cleaners, or iodine-containing cleaners
In response to the recent COVID-19 pandemic, we recommend this additional step to ensure the
product is fully sanitized:
Generously spray alcohol spray or gel (minimum 75% alcohol) and wipe off. Repeat 3-4 times
to
fully disinfect the product. This can be done on the silicone skin and the latex airway.