Doppler Phantom for X-Ray CT, Ultrasound and MRI
Item # TPS-DP-C01Need an estimate?
Click Add To Quote
-
by
A trusted GT partner -
FREE Shipping
U.S. Contiguous States Only -
2-Year Warranty
Provided by manufacturer -
Gov't pricing
Available upon request
Doppler Phantom for X-Ray CT, Ultrasound and MRI
Doppler Phantom serves purposes in medical imaging research, development, training, and testing. The phantom
includes a bone plate simulating the 2D projection of the skull with realistic internal porosity. Internal blood
vessels can be filled with water or commonly used blood-mimicking fluids.
Doppler Phantoms are used for medical imaging research and development, training, and testing purposes. The bone
plate installed on the top of this phantom mimics the skull bone, which in this case simulates only the 2D
projection of the skull with a realistic internal porosity structure. The internal blood vessels can be filled
either with water or with most of the commonly used blood-mimicking fluids. This phantom can be used with
Barium-sulfate, Iodine-based, Gadolinium-based, Microbubble, and Iron Oxide-based contrast mediums.
The phantom can be customized in multiple ways to suit the needs of a wide variety of applications.
Design
- Partial Skull Phantom with a Customized Thickness;
- Filling the Phantom with the Acoustically Correct Brain-Mimicking Material
- Custom Blood Vessels
- Standard Tubes and Connectors Connected to the Custom Vessels
- Incorporating the Phantom within a Standard Compact Box
- Implementing a Thin Film on Top of the Phantom
- Custom Target Wires
- Doppler Phantom
- User Manual/Assembly Instructions
- 2-Year Warranty & Unlimited Customer Service
- Height: 8 x 6 x 4 in (approx.)
- Weight: 1.0 lb (approx.)
- Height: 12 x 10 x 10 in (approx.)
- Weight: 6 lbs (approx.)
- Soft tissue and organs: Composition of urethane-based soft resin
- Synthetic bones: Patented ceramic-reinforced epoxy-based composite material
GTSimulators by Global Technologies
True Phantom Solutions Authorized Dealer
Doppler Phantom for X-Ray CT, Ultrasound and MRI
Phantom Dimensions:- Height: 8 x 6 x 4 in (approx.)
- Weight: 1.0 lb (approx.)
- Height: 12 x 10 x 10 in (approx.)
- Weight: 6 lbs (approx.)
- Soft tissue and organs: Composition of urethane-based soft resin
- Synthetic bones: Patented ceramic-reinforced epoxy-based composite material
Technical Properties
Type of Tissue | Sound Velocity[m/s] | Density [g/cm3] | Attenuation Measured at 2.25 MHz [dB/cm] |
---|---|---|---|
Cortical Bone | 3000 ± 30 | 2.31 | 6.4 ± 0.3 |
Trabecular Bone | 2800 ± 50 | 2.03 | 21 ± 2 |
Brain Matter | 1400 ± 10 | 0.99 | 1.0 ± 0.2 |
Skin Tissue | 1400 ± 10 | 1.02 | 1.7 ± 0.2 |
HU Values of the Tissue Mimicking-Materials
S.No. | Tissue Type | HU Value (average) |
---|---|---|
1 | Brain Tissue | -25 |
2 | Trabecular Bone | 800 |
3 | Cortical Bone | 1300 |
Section Number | Cortical Outer Thickness [mm] | Trabecular Thickness [mm] | Cortical Inner Thickness [mm] | Total Thickness [mm] |
---|---|---|---|---|
A | 1.5 ± 0.2 | 1 ± 0.2 | 1.0 ± 0.2 | 3.5 ± 0.2 |
B | 1.5 ± 0.2 | 2 ± 0.2 | 1.0 ± 0.2 | 4.5 ± 0.2 |
C | 2.5 ± 0.2 | 3m± 0.2 | 1.0 ± 0.2 | 6.5 ± 0.2 |